CMF / CRF Details

CMF ID: 4895

Replace Incandescent Traffic Signal Bulbs with Light Emitting Diodes (LEDs)

Description: At urban signalized intersections, incandescent traffic signal bulbs are replaced by light emitting diodes (LEDs) to improve signal visibility

Prior Condition:  Signal heads at signalized intersections had incandescent bulbs

Category: Intersection traffic control

Study: Safety Evaluation of Converting Traffic Signals from Incandescent to LED Bulbs, Srinivasan et al., 2013

 
Star Quality Rating:3 Stars  [View score details]
Rating Points Total:90
Crash Modification Factor (CMF)
Value:1.122
Adjusted Standard Error:
Unadjusted Standard Error:0.179
Crash Reduction Factor (CRF)
Value:-12.2  (This value indicates an increase in crashes)
Adjusted Standard Error:
Unadjusted Standard Error:17.9
Applicability
Crash Type:Nighttime
Crash Severity:K (fatal),A (serious injury),B (minor injury),C (possible injury)
Roadway Types:Not specified
Street Type:
Minimum Number of Lanes:
Maximum Number of Lanes:
Number of Lanes Direction:
Number of Lanes Comment:
Crash Weather:Not specified
Road Division Type:All
Minimum Speed Limit:
Maximum Speed Limit:
Speed Unit:
Speed Limit Comment:
Area Type:Urban
Traffic Volume:
Average Traffic Volume:
Time of Day:Night
If countermeasure is intersection-based
Intersection Type:Roadway/roadway (not interchange related)
Intersection Geometry:3-leg
Traffic Control:Signalized
Major Road Traffic Volume:
Minor Road Traffic Volume:
Average Major Road Volume :25628 (Total) Annual Average Daily Traffic (AADT)
Average Minor Road Volume :25628 (Total) Annual Average Daily Traffic (AADT)
Development Details
Date Range of Data Used:2005 to 2010
Municipality:Charlotte
State:NC
Country:USA
Type of Methodology Used:Before/after using empirical Bayes or full Bayes
Sample Size (crashes):54 crashes before, 45 crashes after
Other Details
Included in Highway Safety Manual?No
Date Added to Clearinghouse:Aug 01, 2013
Comments: